Electrodialysis reversal can effectively remove ions from water and wastewater by applying a direct current and reversing the polarity of electrodes periodically. The electric charge drives the ions penetrating anion or cation exchange membranes. EDR reduces conductivity and dissolved solids of bulk solution.
Schematic diagram of EDR |
Applications
• Desalination of RO concentrate
• Reclamation of Cooling tower condensate
• Desalination of Salty groundwater
• Treatment of City water
• Reclamation of Wastewater
Patents
• TW I232772, I310451, I356043, I359114
• CN ZL200310121844.3, ZL200810001610.8
• SG 120986
EDR system for river water desalination (2400 m3/d ) |
EDR system for wastewater desalination (400 m3/d) |
Full-Scale Applications of EDR
|
Mr. Liao, Chi-Chung
Tel : 886-3-5732974
Fax : 886-3-5732349
E-mail : ChiChungLiao@itri.org.tw